100A 3 Phase ELCB (Am1L)

Model No. :
Am1L
Mini Order :
≥10 Pieces Negotiable (Pieces)
Production Capacity :
5000 (Pieces) (Day)
Trade Terms :
FOB
Payment Terms:
L/C, T/T, D/P, Paypal
Product Detail
Base Info.
  • 3, 4
  • Low Voltage Circuit Breakers
  • Global
  • 8000
  • AC 400V
  • 100, 225, 400, 630
  • CE, CB, CCC, ISO9001: 2000
  • Moulded Case Circuit Breaker
  • Fixed
  • Air
  • 3, 4
  • AC800
  • Manual Type
  • High-Speed Circuit Breaker
Additional Info.
  • China
  • ANDELI
  • Carton
  • ISO9001-2000,CE,CB,CCC
Product Description
Application

AM1L series earth leakage circuit breaker are one of the new type earth leakage breakerswhich have been developed by the company using international advanced design and manufacturingtechnology. Suitable for a line of AC50Hz/60Hz, rated voltage up to 400V, rated current16A to 630A. And is acted as infrequent changeover of circuit or infrequent starting of motor. Thebreaker has overload, short-circuit and under-voltage protective function, which can protect thecircuit and the power equipment against damage, meanwhile, it can provide protection to thesefire dangers that caused by these long-time existed grounding fault that can not be detected bythe over-current protection.

This breaker can be installed vertically(upright) or horizontally(transverse). Wiring of the breaker can not be in adverse direction, that means power supply line must beconnected to terminal 1, 3 and 5, and the load line connected to terminal 2, 4 and 6. The rated residual operating current In and the maximum breaking time can be adjustedon site according to practical condition.

The leakage protection module still can work normally when the phase voltage reduce to 50V. It has the same overall size with the AM1 series breakers, which make the installation moreexchangeable.

The breakers are suitable for isolation, its symbol are:
The breakers comply with the demands of the following standards:
IEC60947-1 and GB/T 14048.1
GeneralIEC60947-2 and GB 14048.2
Low voltage breakersIEC60947-4 and GB 14048.4
Contactors and motor startersIEC60947-5.1 and GB 14048.5
Electrical equipments of electromechanical control circuit

Outline and Installation Dimension



About us


Type AM1L-100 AM1L-225 AM1L-400 AM1L-630
Frame Current Inm(A) 100 225 400 630
Rated current In(A) (10)16, 20, 25, 32, 40, 50, 63, 80, 100 100, 125, 160, 180, 200, 225 225, 250, 315, 350, 400 400, 500, 630
Pole Number 3 4 3 4 3 4 3 4
Rated Insulation Voltage Ui(V) AC800
Rated Working voltage Ue(V) AC 400V
Rated impulse with stand voltage Uimp(V) 8000
Arc-over Distance(mm) > 50
Breaking capacity grade M H M H M M
Limiting short-circuit breaking capacity lcu (kA) AC400V 50 85 50 50 85 50 65 65
Service short-circuit breaking capacity lcs(kA) AC400V 35 50 35 35 50 35 42 42
Rated residual operating current I n(mA) Non-delay type 100/300/500
Delay type 100/300/500 300/500/1000
Rated residual nonoperatingcurrent I no(mA) 1/2 I n
Operation performance (time) Electrified 1500 1000 1000 1000
Unelectrified 8500 7000 4000 4000